Pollution
  • en
  • it
Pollution
  • Products
    • Environment & Safety
    • Gas | Energy
  • Applications
    • Environment & Safety
      • Outdoor Air Quality
      • Stack Emissions
    • Gas | Energy
      • THT or TBM analysis
  • What’s On
  • Service & Support
    • Our Services
    • Request Assistance
    • Downloads & Media
  • About Us
  • Contacts
    • Contact us
    • Sales Network
    • Work with us

Pyxis GC BTEX

The smart environmental gascromatograph: unique, reliable and versatile for innovative and effiecient monitorings

PyxisGC BTEX is the first “carrier-gas free” gas chromatograph that allows you to remotely monitor BTEX (Benzene, Toluene, Ethylbenzene, and Xylene) in ambient air, in compliance with the EN14662-3:2015 standard. The instrument does not need gas cylinders since the carrier gas is ambient air, allowing installation in any contest without needing staff or additional gas cylinders.

Pyxis GC BTEX combines the Micro-Electro-Mechanical (MEMS) System of microfluidics for the selective pre-concentration and the gaschromatographic separation, with the peak quantification given by the Miniaturized Photoionization Detector (PID).

The BTEX present in the gas sample are physically separated using a micro column chip (proprietary technology). Pyxis GC is also equipped with an auto-check system to verify and eventually correct the instrumental drift, in the long run, guaranteeing data quality. These characteristics allowed bringing to the field the same analytical quality of the lab instruments.

Pyxis GC BTEX is also easy to move, enabling monitoring in every condition: fixed network, on-the-go analysis, emergency events, and focused hot spot campaigns.

Request Information
Data storage

Internal 16 GB flash memroy 16 GB (runtime up to 7 years of continuous measurements)

Power consumption

Max. 25W

Carrier gas

ambient air, <10 sccm

Detector

ultra-sensitive PID, Photo Ionization Detector (10.6 eV)

Analysed Gasses

Benzene, Toluene, Ethylbenzene, Xylenes (other gases on request)

Analytical range

1-200 ppb (benzene) with 10 min analysis cycle

Lower Detection Limit

<0,03 μg/m3 (0,01ppb) of benzene

Communication interfaces

Ethernet, Wi-Fi, 4G

Instrument control and data access
  • Local WebServer, accessible by the most common web browser (IE, Firefox, Chrome)
  • MODBUS on TCP server, API
  • “Pollution Guardian“ IoT Service
Power supply

220v max. 2.5A (UPS and 24V battery version; no UPS and no 12V battery version)

Operating Temperature

from -40°C to 50°C

Dimensions

420mm x 620mm x 210mm

Weight (according to the model)

W0E 11,5 Kg / WCE (auto-calib) 13 Kg / WBE (UPS) 17,5 Kg / WEE (auto-calib+UPS) 19 Kg

Brochure Pyxis BTEX (EN)
File type: Pdf
Size: 1,005.99 KB
Language: EN
Download
Brochure Pyxis BTEX (FR)
File type: Pdf
Size: 999.11 KB
Language: FR
Download
thumbnail of BI-JP0253-0-PyxisGC-BTEX-Brochure-JP
Brochure Pyxis BTEX (JP)
File type: Pdf
Size: 327.94 KB
Language: JP
Download
Technical Report PyxisGC BTEX and Arpa Puglia
File type: Pdf
Size: 2.58 MB
Language: EN
Download
thumbnail of OI-EN0423-0-Case-History-Nave-Scuola-Palinuro-1
Case History Pyxis – Palinuro Training Ship (ENG)
File type: Pdf
Size: 830.31 KB
Language: EN
Download
thumbnail of OI-EN0427-0-Case-History-ARPA-Puglia-Bari
Case History PyxisGC BTEX – ARPA Puglia Bari (ENG)
File type: Pdf
Size: 917.33 KB
Language: EN
Download
thumbnail of OI-EN0425-0-Case-History-ARPA-Puglia-Brindisi
Case History PyxisGC BTEX – ARPA Puglia Brindisi (ENG)
File type: Pdf
Size: 784.36 KB
Language: EN
Download
thumbnail of OI-EN0436-0-Case-History-Autostrada-401
Case History PyxisGC BTEX – Highway 401 (ENG)
File type: Pdf
Size: 569.81 KB
Language: EN
Download
thumbnail of OI-EN0423-0-Case-History-Nave-Scuola-Palinuro-1
Case History PyxisGC BTEX – Palinuro School Ship (ENG)
File type: Pdf
Size: 829.92 KB
Language: EN
Download
thumbnail of OI-EN0432-0-Case-History-Taranto-Molestie-Olfattive
Case History PyxisGC BTEX – Taranto Odour Nuisances (ENG)
File type: Pdf
Size: 926.53 KB
Language: EN
Download
thumbnail of OI-EN0392-0-Case-History-ARPA-Sicilia-EN
Case History PyxisGC BTEX – ARPA Sicilia (ENG)
File type: Pdf
Size: 1.17 MB
Language: EN
Download
thumbnail of OI-EN0399-0-Case-History-Pyxis-Heli-Protection-Europe-EN
Case History PyxisGC BTEX – Heli Protection Europe (EN)
File type: Pdf
Size: 388.92 KB
Language: EN
Download
thumbnail of OI-EN0391-0-Case-History-LabAnalysis-Pyxis-GC-BTEX-EN
Case History PyxisGC BTEX – LabAnalysis (ENG)
File type: Pdf
Size: 615.82 KB
Language: EN
Download
thumbnail of OI-EN0463-0-Case-History-Arpacal
Case History PyxisGC BTEX–Reliables surveys even in harsh environments (ENG)
File type: Pdf
Size: 747.37 KB
Language: EN
Download
PyxisGC BTEX: Direct local connection via Ethernet or Wi-Fi
Watch video
PyxisGC BTEX: GUI – Access and user types
Watch video
PyxisGC BTEX: GUI – Auto-Check
Watch video
PyxisGC BTEX: GUI – Display and edit methods
Watch video
PyxisGC BTEX: GUI – Display trends
Watch video
PyxisGC BTEX: GUI – Home page and general functions
Watch video
PyxisGC BTEX: GUI – Method calibration
Watch video
PyxisGC BTEX: GUI – Settings
Watch video
PyxisGC BTEX: Introduction to PyxisGC BTEX
Watch video
PyxisGC BTEX: Pollution Guardian
Watch video
PyxisGC BTEX
Video Pyxis Smart City
Watch video
Video Pyxis Fenceline
Watch video
BTEX in aria ambiente
BTEX analysis

Benzene is a hydrocarbon that appears as a volatile liquid, capable of evaporating rapidly at room temperature; it is colourless and easily flammable and is the progenitor of a family of organic compounds defined as aromatic, due to the characteristic odour. Benzene is a natural component of oil (1-5% by volume) and its refining derivatives. The carcinogenic […]

Città con connessioni
Outdoor air quality in Smart City

A SMART CITY is a city that uses smart technologies to make the critical infrastructure components and services of the city (including public administration, education, environment, healthcare, public safety, transportation and utilities) more intelligent, interconnected and efficient, with the aim of becoming more sustainable, fair and livable. A Smart City is therefore a city that guarantees a […]

Pollution Guardian

Pollution Guardian

Ultrasonic Anemometer

Market:

Environment & Safety

Compounds:

(C2H5)C6H5, (CH3)2C6H4, C6H6, C7H8

Technology:

GC, microGC, PID

Brand:

Pollution

Pollution

POLLUTION S.r.l.
Via Guizzardi, 52 – 40054
Budrio (Bologna) – ITALY
pollution@pollution.it

  • Terms & Conditions
  • Privacy Policy
  • Cookie Policy
  • Send Whistleblowing
  • Whistleblowing Policy
Pollution
Pollution
Pollution
Pollution
Pollution
Pollution Srl - P.Iva: 00694631201 - C.F.: 04051900373 - R.E.A.: 335338 Bologna - Codice Destinatario SdI: M5UXCR1